Power Distribution
Knurr DI-STRIP Basic Rack PDUs
Product Brochure
Relative Humidity | 5% to 95% |
0U Units Width x Depth | 45 mm x 46 mm (1.77in x 1.81in) and others |
0U Units Length | 333 mm - 1833 mm (13 in - 72 in) |
Input Power Options | 100 - 120V 1-ph 15/20/30A |
Maximum Outlets | Max. 48 |
Maximum Operating Temp. Range | 0 Degree C to 45/55 Degree C (32 Degree F to 113/131 Degree F) |
Storage Temperature Range | -20 Degree C to - 85 Degree C (-4 Degree F to -121 Degree F) |
Benefits:
Designed for High Availability
- Designed specifically to accommodate higher power densities and be resistant to higher temperatures.
- Energy metering provides users the information to maximize data center power and cooling infrastructure.
- Allows user to add individual hot-swappable output power modules for capacity as demand grows.
- Offers the ability to change input capacity or configuration while maintaining Rack PDU infrastructure.
- Designed to Enhance Energy Efficiency and Capacity Management
- Flexibility to respond to constant change—redeploy modules to suit changing needs.
- Adaptive capacity, distribution, monitoring, control and management of critical devices.
- Scalable design that allows onsite configuration to fit immediate IT equipment needs.
- Provides a wide selection of single phase and three-phase power input configurations—with the ability to field change while maintaining distribution infrastructure.
- Employs energy efficient receptacle control technology.
- Expanded branch overload protection minimizes threat of cascading PDU overload.
Designed to Improve Business Resiliency and Agility:
- Provides for local or remote monitoring and management of connected loads.
- Easily integrate with existing network and security architectures, as well as higher level management software – allowing you to operate at peak velocity.
- Preemptive notifications before problems occur.
- Allows user to shut down non-essential equipment during power outages to maximize availability and back-up power.
- Provides a compatible monitoring platform for MPH, offering seamless common operation if deployed together.
Designed to Reduce Deployment Time and Expenses:
- Allows real-time, highly precise metering and management – and the lowest energy consumption in the industry for rack PDUs.
- Provides the most cost-effective design available—build, add on, or modify the platform design.
- Allows redeployment of modules to suit changing needs.
- Rack PDUs may be pre-installed.
Features:
- Modular input power
- Hot Swappable output power
- Receptacles & modules
- Monitors at branch level
- Controls at equipment level
- Offers single-phase and three-phase models
Liebert FPC Power Distribution Cabinet
Product Brochure
Usage/Application | Industrial |
Frequency Deviation | +-0.5Hz |
Storage Temperature Range | -67 Degree to +185 Degree F (-55 Degree to +85 Degree C) |
Operating Temperature Range | +32 Degree to 104 Degree F (0 Degree to 40 Degree C) |
Relative Humidity | 0% to 95% without condensing |
Operating Altitude | Max. 6,600 ft. (2,000m) above Mean Sea Level |
Country of Origin | Made in India |
The rack-size Liebert® FPC power conditioning and distribution cabinet provides high quality, flexible power distribution for high-density data centers. It is engineered to combine the convenience and cost savings of a pre-packaged, factory-tested unit with the flexibility of a custom-tailored power system. This self-contained system provides power isolation, power distribution, computer-grade grounding and power monitoring. Liebert FPC ranges in capacity from 15kVA to 300kVA, 60Hz or 50Hz models. The system is available in 23.5" cabinet and 47” cabinet sizes and is designed to fit at the end of, or within, a row of racks, as well as in a standalone configuration.
Benefits:
- Sub-feed breakers or I-Line panelboards provide the flexibility to add distribution capacity as needed to adapt to growing room loads.
- Inline 42-pole panelboards provide wide-open wiring access channels for easy installation of additional circuits.
- Various cabling options provide flexibility - top of the racks, under the floor or through the bottom of the cabinet.
- Factory testing ensures reliable, consistent performance.
- Local and remote power monitoring capabilities enable you to attain maximum availability for your critical operations.
- Four panelboard capacity saves money by eliminating need for multiple cabinets.
- Ability to install additional distribution capacity within the same cabinet as needs change helps to manage costs over service life of system.
- Larger kVA capacity rating means fewer units will be needed to support IT growth.
- In-rack location places power distribution closer to the load, reducing under floor cabling from centralized UPS and making cable movements simpler and less expensive.
Features:
- Rack-size power conditioning and distribution
- Requires only front and back service access
- Offers top or bottom cable entry
Liebert SPM 2.0
Product Brochure
Nominal Input Voltage | 380V; 50Hz; 3 phase, 5 wires |
Weight | 300kg |
Capacity | 20 kVA |
Output Voltage | Single phase, 3 wires; 3 phase, 5 wires |
Protection Level | IP20/IP30 |
Dimensions (W x D x H)(mm) | 600 x 1100 x 2000 |
Features:
- Two Dimensions of Modularity
- Hot Pluggable Modules
- Hot Pluggable Branch Feeders
- Compact Footprint- High-density design
- Intuitive 9" Touch Screen Display
- Micro Power Management
- Branch Circuit Monitoring
- Breaker Positioning Monitoring
- Real-time Waveform Monitoring
- Online Report Generation
- Two Level User-Configurable Alarms
- Single or Dual Input Power Supply
- 144 No power distribution poles
- Remote Monitoring Facility
- Built-in Top/Bottom Cable Entry for Raised / Non-raised Floor applications
- Optional TVSS and Isolation Transformer
- Factory assembled & Tested
- CE & CCC Certified
Vertiv Geist rPDU Basic
Product Brochure
Voltage | 230 V |
Phase | Single Phase |
Size | 10xC13 | 2xC19 |
Rack | 1U (Rack) |
Model Number | VP9559 |
Current | 16 A |
Frequency | 50 Hz |
Benefits:
- Reliable power distribution to critical IT equipment.
- Fast, inexpensive customization, including non-standard cord lengths
- Standard three-year warranty, upgraded to five years with product registration.
Features:
- Available in vertical and horizontal rackmount form factors.
- Flexibility to meet a broad range of requirements, with a variety of electrical and receptacle configurations available.
- Simple and quick installation in all standard racks or cabinets with included mounting brackets.
Available Models:
VP9559
16 A C20 power Inlet, 230 V 230 V 10xC13 | 2xC19 1U (Rack)
VP7552
16 A C20 power Inlet, 230 V 230 V 20xC13 | 4xC19 0U (Rack)
VP7553
32 A IEC60309 1ph/N/PE, 230 V 230 V 20xC13 | 4xC19 0U (Rack)
VP7551
16 A IEC60309 1ph/N/PE, 230 V 230 V 20xC13 | 4xC19 0U (Rack)
VP7557
16 A IEC60309 3ph/N/PE, 230/400V 230 V 36xC13 | 6xC19 0U (Rack)
Vertiv Geist rPDU Monitored
Product Brochure
Current | 16A |
Nominal Input Voltage | 230 V |
Input Frequency | 50 Hz |
Rack | 0U (Rack) |
Size | 18xC13 | 2xC19 |
Model Number | VP8858 |
Phase | Single Phase |
Benefits
- Reliable power distribution with local and remote power monitoring options offer quick access to critical power usage information to evaluate energy usage trends and maximize uptime.
- Environmental monitoring capabilities ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime.
- Upgrade your hot-swappable monitoring device on the fly to leverage new technologies and accommodate changing business needs without having to replace entire power strips.
- Simplify circuit and phase balancing with color-coded receptacles.
- Monitor power consumption at the outlet-level for a detailed view of the power distributed to specific equipment with the outlet level option.
- Gather comprehensive power data at the palm of your hand with the use of the Vertiv VLC mobile app.
- Every unit is 100% tested for reliability and functionality to ensure units function as designed.
- Standard three-year warranty, upgraded to five years with product registration.
- Hot-Swappable and upgradeable monitoring device.
- Local and remote power monitoring with an accuracy of +/- 1% (ANSI & IEC Standards).
- VLC (Visible Light Communication).
- Environmental monitoring with the addition of optional sensors.
- High-Temperature Grade 60°C for high-temperature environments.
- Flexibility to meet a broad range of requirements, with a variety of electrical and receptacle configurations available.
- Simple and quick installation in all standard racks or cabinets with included mounting brackets.
The Monitored PDU offers real-time power consumption metrics and Email & SNMP alarming for voltage, real power, apparent power, power factor, amperage and kilowatt-hours at the rack and via a secure web interface. The PDU offers important insights enabling the user to balance loads, evaluate energy usage trends, and ensure maximum uptime.
VP8858
16 A C20 power Inlet, 230 V 230 V 18xC13 | 2xC19 0U (Rack)
VP8853
32 A IEC60309 1ph/N/PE, 230 V 230 V 36xC13 | 6xC19 0U (Rack)
VP8881
16 A IEC60309 3ph/N/PE, 230/400V 230 V 36xC13 | 6xC19 0U (Rack)
VP8886
32 A IEC60309 3ph/N/PE, 230/400V 230 V 30xC13 | 12xC19 0U (Rack)
Vertiv Geist rPDU Switched
Product Brochure
Current | 16A |
Nominal Input Voltage | 230 V |
Input Frequency | 50 Hz |
Size | 21xC13 (U-Lock) | 3xC19 (U-Lock) |
Rack | 0U (Rack) |
Model Number | VP8959EU3 |
Phase | Single Phase |
Country of Origin | Made in India |
Benefits:
- Outlet level control to turn on, turn off or reboot individual outlets.
- Bi-Stable latching relays significantly reduce idle power draw.
- Upgradeable and Hot-Swappable monitoring device
- Local and remote power monitoring with an accuracy of +/- 1% (ANSI & IEC Standards)
- VLC (Visible Light Communication)
- Environmental monitoring with the addition of optional sensors.
- High-Temperature Grade 60 °C for high-temperature environments.
- Color-coded U-Lock receptacles by a circuit for instant identification.
- Flexibility to meet a broad range of requirements, with a variety of electrical and receptacle configurations available.
- Simple and quick installation in all standard racks or cabinets with included mounting brackets.
Features:
- Avoid potential circuit overloads with remote current metering and monitoring of connected loads.
- Power sequencing time delays allow users to define the order in which to power up or down connected equipment to avoid circuit overload.
- Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control.
- Reliable power distribution with local and remote power monitoring options offer quick access to critical power usage information to evaluate energy usage trends and maximize uptime.
- Environmental monitoring capabilities ensure users have critical infrastructure data at their fingertips.
- Upgrade your hot-swappable monitoring device on the fly to leverage new technologies and accommodate changing business needs without having to replace entire power strips.
- U-Lock receptacles secure power cords and avoid accidental disconnections.
- Simplify circuit and phase balancing with color-coded receptacles.
- Monitor power consumption at the outlet-level for a detailed view of the power distributed to specific equipment with the outlet level option.
- Gather comprehensive power data at the palm of your hand with the use of the Vertiv VLC mobile app.
- Standard three-year warranty, upgraded to five years with product registration.
The Switched PDU offers real-time power consumption metrics and Email & SNMP alarming for voltage, real power, apparent power, power factor, amperage and kilowatt-hours at the rack and via secure web interface along with remote outlet control. The PDU offers important insights enabling the user to balance loads, evaluate energy usage trends, and ensure maximum uptime.
VP8959EU3
16 A IEC60320 C20 power Inlet, 230 V 230 V 21xC13 (U-Lock) | 3xC19 (U-Lock) 0U (Rack)
VP8953
32 A IEC60309 1ph/N/PE, 230 V 230 V 20xC13 (U-Lock) | 4xC19 (U-Lock) 0U (Rack)
IMD-03
rPDU (Upgradeable unit)
MPHI Managed Rack PDU: Advanced Monitoring and Control
Product Brochure
Mounting | Shipped with universal Mounting Bracket |
Input Wiring Option | 3 Meter Cord with IEC60309 Plug |
Relative Humidity | 5% - 95 % RH non-condensing |
Maximum Operating Temp. Range | 0 Degree C to 60 Degree C (32 Degree F to 140 Degree F) |
Input Power Options | 230 V 1-ph 16/32A 230/400 V 3-ph 32A |
0U Units Width x Depth | ~56mm x 70mm (2.2in x 2.7in) |
0U Units Maximum Length | 1830 mm |
Benefits:
- Monitors electrical and environmental parameters with set threshold and alarm tools
- Controls and manages individual receptacles and/or groups of loads and devices
- Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
- Energy and power metering to maximize the data centre power and cooling infrastructure
- Up to Eight MPHI rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring
Features:
- Industry leading operating temperature - Up to 60หC / 140หF to support increasingly hot exhaust side Environment
- Energy and power metering - Down to the individual receptacle to optimize the data centre power and cooling infrastructure
- Up to Eight MPHI rack PDUs may be interconnected - As a Rack PDU Array, consolidating user IP connections and device monitoring
Available in many options:
- Outlet Level Metered and Switched
- Outlet Level Metered
- Rack PDU Metered and Outlet Switched
Vertiv MPE Rack PDU
Product Brochure
Length | 826.5 mm and 1736.5 mm |
Operating Altitude | Max. 3000 m |
Relative Humidity | 10 - 90% non-condensing |
Width x Depth | 56 mm x 50 mm |
Storage Temperature | -20 Degree C - 85 Degree C |
During Operation | 5 Degree C - 60 Degree C |
Country of Origin | Made in India |
The MPE Rack PDU is a power distribution unit for data center applications. It offers you the highest level of availability for your critical loads such as 60°C operating temperature. Simple physical and electrical installation helps to keep costs down and to save time during installation.
Benefits:
- Vertiv supplies the PDUs preinstalled in racks which saves extra work on-site.
- Flexible cable entry facilitates installation in the rack.
- Very low unit profile – even in the overload switch area– leaves maximum installation space for other componentsas well as more space for air supply in the rack.
- Models with fixed connection facilitate customer-sideconnection of the input cable for special requirements.
- "SpeedMount" function for installation in Knurr DCM /InstaRack saves time and money in on-site installation.
- Great model variety with power supply from up to three-phase 32 A and a number of different outputs –including country-specific with Schuko plug, UK or Switzerland.
Features:
- Its high operating temperature of up to 60°C makes it suitable for installation in hot aisles (area at the back ofthe rack).
- 20 A overload switch for many 32 A models that prevents the overload switch from triggering prematurelyat high temperatures and during start-up peaks.
- Output cable with disconnection protection to prevent the IEC60320 connection cable from being unintentionally disconnected.
- Stable aluminum housing supports the mechanicalstability of the housing.
- Extra-large wire cross-sectional area of the input cable in three-phase models, this makes it possible to subject the neutral wire to greater loads in the event that the loads are unbalanced.
Vertiv MPH2 B Model Managed Rack PDUs - PDU Level Metered
Product Brochure
0U units Length | 916 mm / 1004 mm / 1737 mm/ 1827 mm; (36 in) / (39.5 in) / (68.4 in) / (72 in) |
0U Units Width x Depth | 0U Low profile: 56mm x 5mm(2.2in x 1.96in) 0U Standard: 56mm x 70mm(2.2in x 2.7in) |
Idle Power Consumption | 3W - 5W |
Maximum Operating Temp. Range | 0 Degree C to 60 Degree C (32 Degree F to 140 Degree F) |
Storage Temperature Range | -25 Degree C to 85 Degree C (-13 Degree F to 185 Degree F) |
Relative Humidity | 5% to 95% |
Input Wiring Options | 10 ft. pluggable power cord or Hardwired |
Metering Accuracy | +/-1% |
Vertiv MPH2 Managed Rack PDU offerings deliver remote monitoring and control capabilities in a range of models. The Vertiv MPH2-B provides basic power monitoring. Available in a range of form factors, each MPH2-B models provides metering at the input and branch level. Warranty: 2 Year Full Coverage Factory Warranty – Optional Extended Warranty Available
Benefits:
- Monitors electrical and environmental parameters with set threshold and alarm tools
- Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
- Energy and power metering to maximize the data center power and cooling infrastructure
- Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
- Up to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.
Features:
- Industry leading operating temperature — up to 60หC / 140หF to support hot Internal rack environments
- Bi-stable relays ensure basic power distribution in the event that intelligence is compromised
- Accurate power metering of +/-1% voltage & current for assured oversight
- Energy and power metering at the input and branch
- Comprehensive alarming including notification of overloaded branch circuits
- Environmental sensing with threshold and alarm set-points
- Notification on the loss or removal of individual rack equipment loads
Vertiv MPH2 C Model Managed Rack PDUs - PDU Level Metered and Outlet Switched
Product Brochure
Storage Temperature Range | -25 Degree C to 85 Degree C (-13 Degree F to 185 Degree F) |
Relative Humidity | 5% to 95% |
Idle Power Consumption | 3W - 5W |
Metering Accuracy | +/-1% |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Input Wiring Options | 10 ft. pluggable power cord or Hardwired |
Max. Capacity International | 22.2 kW |
Maximum Operating Temp. Range | 0 Degree C to 60 Degree C (32 Degree F to 140 Degree F) |
Vertiv MPH2 Managed Rack PDU offerings deliver remote monitoring and control capabilities in a range of models. The Vertiv MPH2-C provides basic power monitoring and power control at the outlet level. Available in a range of form factors, each MPH2-C model provides metering at the input and branch level and on/off power control of individual outlets.
Warranty: 2 Year Full Coverage Factory Warranty – Optional Extended Warranty Available
Benefits:
- Monitors electrical and environmental parameters with set threshold and alarm tools
- Controls and manages individual receptacles and/or groups of loads and devices
- Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
- Energy and power metering to maximize the data center power and cooling infrastructure
- Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
- Up to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.
Features:
- Industry leading operating temperature — up to 60หC / 140หF to support hot Internal rack environments
- Bi-stable relays ensure basic power distribution in the event that intelligence is compromised
- Accurate power metering of +/-1% voltage & current for assured oversight
- Energy and power metering down to the individual receptacle
- Comprehensive alarming including notification of overloaded branch circuits
- Environmental sensing with threshold and alarm set-points
- Notification on the loss or removal of individual rack equipment loads
Available Models:
- Vertiv MPH2 MPHC1111
- Vertiv MPH2 MPHC1112
Vertiv MPH2 M Model Managed Rack PDUs - Outlet Level Metered
Product Brochure
Metering Accuracy | +/-1% |
Input Wiring Options | 10 ft. pluggable power cord or Hardwired |
Maximum Outlets | Strip Metered: 42 Outlet Metered and / or Switched: 24 |
0U units Length | 916 mm / 1004 mm / 1737 mm/ 1827 mm; (36 in) / (39.5 in) / (68.4 in) / (72 in) |
Idle Power Consumption | 3W - 5W |
0U Units Width x Depth | 0U Low profile: 56mm x 5mm(2.2in x 1.96in) 0U Standard: 56mm x 70mm(2.2in x 2.7in) |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Max. Capacity North America | 17.2 kW |
Max. Capacity Internationa | 22.2 kW |
Vertiv MPH2 Managed Rack PDU offerings deliver remote monitoring and control capabilities in a range of models. The Vertiv MPH2-M is designed for environments where power usage needs to be captured in discrete increments. Available in a range of form factors, each MPH2-M models provides a clear view of usage and the ability to segment data by the input, branch and receptacle.
Warranty: 2 Year Full Coverage Factory Warranty – Optional Extended Warranty Available
Benefits:
- Monitors electrical and environmental parameters with set threshold and alarm tools
- Controls and manages individual receptacles and/or groups of loads and devices
- Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
- Energy and power metering to maximize the data center power and cooling infrastructure
- Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
- Up to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.
Features:
- Industry leading operating temperature — up to 60หC / 140หF to support hot Internal rack environments
- Bi-stable relays ensure basic power distribution in the event that intelligence is compromised
- Accurate power metering of +/-1% voltage & current for assured oversight
- Energy and power metering down to the individual receptacle
- Comprehensive alarming including notification of overloaded branch circuits
- Environmental sensing with threshold and alarm set-points
- Notification on the loss or removal of individual rack equipment loads
Available Models:
- Vertiv MPH2 MPHM1111
- Vertiv MPH2 MPHM1112
Vertiv MPH2 R Model Managed Rack PDUs - Outlet Level Metered and Switched
Product Brochure
Maximum Outlets | Strip Metered: 42 Outlet Metered and / or Switched: 24 |
Storage Temperature Range | -25 Degree C to 85 Degree C (-13 Degree F to 185 Degree F) |
Idle Power Consumption | 3W - 5W |
0U Units Width x Depth | 0U Low profile: 56mm x 5mm(2.2in x 1.96in) 0U Standard: 56mm x 70mm(2.2in x 2.7in) |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Input Wiring Options | 10 ft. pluggable power cord or Hardwired |
Max. Capacity International | 22.2 kW |
Maximum Operating Temp. Range | 0 Degree C to 60 Degree C (32 Degree F to 140 Degree F) |
Relative Humidity | 5% to 95% |
Benefits:
- Monitors electrical and environmental parameters with set threshold and alarm tools
- Controls and manages individual receptacles and/or groups of loads and devices
- Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime
- Energy and power metering to maximize the data center power and cooling infrastructure
- Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
- Up to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring.
Features:
- Industry leading operating temperature — up to 60C / 140F to support hot Internal rack environments
- Bi-stable relays ensure basic power distribution in the event that intelligence is compromised
- Accurate power metering of +/-1% voltage & current for assured oversight
- Energy and power metering down to the individual receptacle
- Comprehensive alarming including notification of overloaded branch circuits
- Environmental sensing with threshold and alarm set-points
- Notification on the loss or removal of individual rack equipment loads
Available Models:
- Vertiv MPH2 MPHR1112
- Vertiv MPH2 MPHR1121
- Vertiv MPH2 MPHR1122
- Vertiv MPH2 MPHR1123
- Vertiv MPH2 MPHR1124
- Vertiv MPH2 MPHR1125
- Vertiv MPH2 MPHR1131
- Vertiv MPH2 MPHR1141
- Vertiv MPH2 MPHR1154
- Vertiv MPH2 MPHR1156
- Vertiv MPH2 MPHR1212
- Vertiv MPH2 MPHR1213
- Vertiv MPH2 MPHR1223
- Vertiv MPH2 MPHR1214
- Vertiv MPH2 MPHR1215
- Vertiv MPH2 MPHR1241
- Vertiv MPH2 MPHR1325
- Vertiv MPH2 MPHR1331
- Vertiv MPH2 MPHR1331
- Vertiv MPH2 MPHR1331
- Vertiv MPH2 MPHR1331
Vertiv MPH2 Managed Rack PDU
Product Brochure
Length | 916 mm / 1004 mm / 1737 mm/ 1827 mm |
During Operation | 5 Degree C - 60 Degree C |
Storage Temperature | -20 Degree C - 85 Degree C |
Relative Humidity | 10 - 90% non-condensing |
Operating Altitude | Max. 2000 m |
Width x Depth | 56 mm x 50 mm |
The Vertiv MPH2 Managed Rack PDU is a power supply system with monitoring and control functions. The Vertiv MPH2 offers outstanding features such as easy rack integration and management architecture as well as optimum availability and energy efficiency.
Warranty: Standard warranty is 2 years. Warranty extensions 1 year and 3 years are possible.
Vertiv MPH2 B: Metering per phase and per group. Vertiv MPH2 C: Metering per phase and per group. Each outlet can also be individually switched remotely. Vertiv MPH2 M: Metering per phase, per group and per outlet. Vertiv MPH2 R: Metering per phase, per group and per outlet. Each outlet can also be individually switched remotely.
Benefits:
- Monitors electrical and environmental parameters with defined thresholds and alarm tools
- Additional metering of the neutral conductor and of the crest factor
- Energy and power metering maximize the data center power and cooling infrastructure
- Variety of measurements allows to predict failing conditions before they occur
- Lower power consumptions of all switched rack PDU
- "LongLifeSwitching" technology protects the relay contacts
- Up to four rack Vertiv MPH2 PDUs can be connected in a rack PDU array
- "SpeedMount" function for installation in Vertiv Knürr DCM / InstaRack saves time and money in on-site installations
- Can be delivered pre-installed Knürr racks to save time and costs
Features:
- Industry leading operating temperatures of up to 60 °C suitable for high temperatures inside racks
- Bistable relays ensure basic power supply even when shortfall occurs elsewhere
- Extensive alarm functions including notifications when an alarms occurs in individual groups
- Accurate voltage and current metering up to outlet level with ± 1% tolerance deliver reliable results
- Monitoring of environment conditions (temperature, humidity and input contacts)
- Modular communication card that can be replaced during the operations
- Notification upon failure or if loads are removed in individual racks
Vertiv MPX Adaptive Rack PDU
Product Brochure
Mounting | Shipped with universal Mounting Bracket |
Input Wiring Option | 3 Meter Cord with IEC60309 Plug |
0U Units Width x Depth | ~56mm x 70mm (2.2in x 2.7in) |
0U Units Maximum Length | 1830 mm |
Maximum Operating Temp. Range | 0 Degree C to 60 Degree C (32 Degree F to 140 Degree F) |
Relative Humidity | 5% - 95 % RH non-condensing |
Input Power Options | 230 V 1-ph 16/32A 230/400 V 3-ph 32A |
Available Models:
- Vertiv MPX BRM Output module E – Elementary
- Vertiv MPX BRM Output module B - Branch monitored
- Vertiv MPX BRM Output module R – Receptacle managed
- Vertiv MPX PEM Input module Elementary
- Vertiv MPX PEM Input module Monitored
- Vertiv MPX Power Rail Chassis
Benefits:
High availability
- Heat resistant up to 60 °C ensuring reliable operation in the warm aisle
- Modular hot-swap-enabled output module, controller card and sensors that can be exchanged or updated during operation
- Special relays - connected servers have an uninterrupted power supply even in the event of failure
- Redundant power supply for control electronics
- Fixed databus on the busbar
- Additional metering of the neutral conductor and crest factor
- Data tapping on the Power Entry Module without any additional external monitoring devices
High flexibility:
- One busbar for different networks and power levels - input module can be freely selected. All other components are hot-swap-enabled when running operation
- Mobile display for reading all MPX data on the rack
- All modules configured in line with requirements - patented quick mount fitting for safe installation
- Wide selection of single or three phase power input configurations with ability to field change while maintaining distribution infrastructure
- Scalable design that allows on-site configuration to fit immediate IT requirement''s needs
Highest possible power levels:
- Power feed of maximum 3x63 A - optimal for Blade server applications
- One IP address for up to 4 rails with 28 modules
- Plug and Play for numerous sensors
- Extensive monitoring with a metering accuracy of ± 1 % right through to output level
- AutoDetect function with operating software for modules and sensors
- Minimal power loss for MPX systems
Features:
Industry leading operating temperatures of up to 60 °C suitable for high temperatures inside racks
- Special relays ensure basic power supply even when shortfall occurs elsewhere
- Extensive alarm functions including notifications when an alarms occurs in individual groups
- Accurate voltage and current metering up to outlet level with ± 1% tolerance deliver reliable results
- Monitoring of environment conditions (temperature, humidity and input contacts)
- Modular hot swappable components that can be replaced during the operations
- Notification upon failure or if loads are removed in individual racks
Vertiv MPX Adaptive Rack PDU - Elementary Branch Receptacle Modules
Product Brochure
Max. Capacity North America | 17.2 kW |
Max. Capacity Internatioanal | 27.7 kW |
Idle Power Consumption | 3 W - 22 W |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Input Wiring Options | 10 ft. pluggable power cord |
Relative Humidity | 5% to 95% |
0U Units Width x Depth | 75 mm x 104 mm (2.95 in x 4.09 in) |
0U Units Length | 1035 mm / 1880 mm (40.7 in / 74 in) |
Standard Warranty | 2 years; Extended Warranties Available |
Metering Accuracy | +/-1% |
Maximum Operating Temp. Range | 0 Degree C to 55 Degree C (32 Degree F to 131 Degree F) |
Storage Temperature Range | -25 Degree C to 85 Degree C (-13 Degree F to 185 Degree F) |
MPX is the most responsive and adaptive rack PDU available. With MPX rack PDU technology, you can respond to rack equipment changes and dynamic capacities by leveraging hot-swappable modular output power, hot-swappable modular communications and modular input power. The MPX-E provides basic power distribution without measurement and control. An upgrade to modular power distribution with measurement on the input is available by adding the appropriate output modules.
Benefits:
Designed for High Availability
- Designed specifically to accommodate higher power densities and be resistant to higher temperatures.
- Energy metering provides users the information to maximize data center power and cooling infrastructure.
- Allows user to add individual hot-swappable output power modules for capacity as demand grows.
- Offers the ability to change input capacity or configuration while maintaining Rack PDU infrastructure.
- Designed to Enhance Energy Efficiency and Capacity Management
- Flexibility to respond to constant change—redeploy modules to suit changing needs.
- Adaptive capacity, distribution, monitoring, control and management of critical devices.
- Scalable design that allows onsite configuration to fit immediate IT equipment needs.
- Provides a wide selection of single phase and three-phase power input configurations—with the ability to field change while maintaining distribution infrastructure.
- Employs energy efficient receptacle control technology.
- Expanded branch overload protection minimizes threat of cascading PDU overload.
Designed to Improve Business Resiliency and Agility:
- Provides for local or remote monitoring and management of connected loads.
- Easily integrate with existing network and security architectures, as well as higher level management software – allowing you to operate at peak velocity.
- Preemptive notifications before problems occur.
- Allows user to shut down non-essential equipment during power outages to maximize availability and back-up power.
- Provides a compatible monitoring platform for MPH, offering seamless common operation if deployed together.
Designed to Reduce Deployment Time and Expenses:
- Allows real-time, highly precise metering and management – and the lowest energy consumption in the industry for rack PDUs.
- Provides the most cost-effective design available—build, add on, or modify the platform design.
- Allows redeployment of modules to suit changing needs.
- Rack PDUs may be pre-installed.
Features:
- Modular input power
- Hot Swappable output power
- Receptacles & modules
- Monitors at branch level
- Controls at equipment level
- Offers single-phase and three-phase models
Vertiv MPX Adaptive Rack PDU - with Branch Monitoring Receptacle Modules
Product Brochure
Metering Accuracy | +/-1% |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Input Wiring Options | 10 ft. pluggable power cord |
Max. Capacity North America | 17.2 kW |
Max. Capacity International | 27.7 kW |
Idle Power Consumption | 3 W - 22 W |
0U Units Width x Depth | 75 mm x 104 mm (2.95 in x 4.09 in) |
0U Units Length | 1035 mm / 1880 mm (40.7 in / 74 in) |
Benefits:
Designed for High Availability
- Designed specifically to accommodate higher power densities and be resistant to higher temperatures.
- Energy metering provides users the information to maximize data center power and cooling infrastructure.
- Allows user to add individual hot-swappable output power modules for capacity as demand grows.
- Offers the ability to change input capacity or configuration while maintaining Rack PDU infrastructure.
- Designed to Enhance Energy Efficiency and Capacity Management
- Flexibility to respond to constant change—redeploy modules to suit changing needs.
- Adaptive capacity, distribution, monitoring, control and management of critical devices.
- Scalable design that allows onsite configuration to fit immediate IT equipment needs.
- Provides a wide selection of single phase and three-phase power input configurations—with the ability to field change while maintaining distribution infrastructure.
- Employs energy efficient receptacle control technology.
- Expanded branch overload protection minimizes threat of cascading PDU overload.
Designed to Improve Business Resiliency and Agility:
- Provides for local or remote monitoring and management of connected loads.
- Easily integrate with existing network and security architectures, as well as higher level management software – allowing you to operate at peak velocity.
- Preemptive notifications before problems occur.
- Allows user to shut down non-essential equipment during power outages to maximize availability and back-up power.
- Provides a compatible monitoring platform for MPH, offering seamless common operation if deployed together.
Designed to Reduce Deployment Time and Expenses:
- Allows real-time, highly precise metering and management – and the lowest energy consumption in the industry for rack PDUs.
- Provides the most cost-effective design available—build, add on, or modify the platform design.
- Allows redeployment of modules to suit changing needs.
- Rack PDUs may be pre-installed.
Features:
- Modular input power
- Hot Swappable output power
- Receptacles & modules
- Monitors at branch level
- Controls at equipment level
- Offers single-phase and three-phase models
Vertiv MPX Adaptive Rack PDU - with Receptacle Managed Branch Receptacle Modules
Product Brochure
Input Wiring Options | 10 ft. pluggable power cord |
Max. Capacity North America | 17.2 kW |
Storage Temperature Range | -25 Degree C to 85 Degree C (-13 Degree F to 185 Degree F) |
Relative Humidity | 5% to 95% |
0U Units Length | 1035 mm / 1880 mm (40.7 in / 74 in) |
Input Power Options International | 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A |
Max. Capacity International | 27.7 kW |
Maximum Operating Temp. Range | 0 Degree C to 55 Degree C (32 Degree F to 131 Degree F) |
Idle Power Consumption | 3 W - 22 W |
0U Units Width x Depth | 75 mm x 104 mm (2.95 in x 4.09 in) |
Benefits:
Designed for High Availability
- Designed specifically to accommodate higher power densities and be resistant to higher temperatures.
- Energy metering provides users the information to maximize data center power and cooling infrastructure.
- Allows user to add individual hot-swappable output power modules for capacity as demand grows.
- Offers the ability to change input capacity or configuration while maintaining Rack PDU infrastructure.
Designed to Enhance Energy Efficiency and Capacity Management:
- Flexibility to respond to constant change—redeploy modules to suit changing needs.
- Adaptive capacity, distribution, monitoring, control and management of critical devices.
- Scalable design that allows onsite configuration to fit immediate IT equipment needs.
- Provides a wide selection of single phase and three-phase power input configurations—with the ability to field change while maintaining distribution infrastructure.
- Employs energy efficient receptacle control technology.
- Expanded branch overload protection minimizes threat of cascading PDU overload.
Designed to Improve Business Resiliency and Agility:
- Provides for local or remote monitoring and management of connected loads.
- Easily integrate with existing network and security architectures, as well as higher level management software – allowing you to operate at peak velocity.
- Preemptive notifications before problems occur.
- Allows user to shut down non-essential equipment during power outages to maximize availability and back-up power.
- Provides a compatible monitoring platform for MPH, offering seamless common operation if deployed together.
Designed to Reduce Deployment Time and Expenses:
- Allows real-time, highly precise metering and management – and the lowest energy consumption in the industry for rack PDUs.
- Provides the most cost-effective design available—build, add on, or modify the platform design.
- Allows redeployment of modules to suit changing needs.
- Rack PDUs may be pre-installed.
Features:
- Modular input power
- Hot Swappable output power
- Receptacles & modules
- Monitors at branch level
- Controls at equipment level
- Offers single-phase and three-phase models
Vertiv Knurr PTR2 Power Rack
Product Brochure
Jumpering Space | Front: 80 mm |
Load Rating | 8000 N static |
Protection Rating | IP 20 |
Basic Rack | Extruded Aluminum |
Surface Finish | Powder Coated |
Country of Origin | Made in India |
The Vertiv Knürr PowerTrans2 forms the interface between the low-voltage power supply and rack power distribution as well as further components for supplying servers and other IT devices. It has a modular design with versatile plug in units that can be used as required.
Vertiv Knürr PowerTrans2 - 19' Power Distribution Rack: Available in Monitored and Elementary version, both versions comes with 250 A circuit breaker in the input and provides feed of two separate 3-phase 400 V mains. Vertiv Knürr PowerTrans2 - 19' Slot-in Power Distributor. Vertiv Knürr PowerTrans2 – Connection Cable: to establish the connection between 19' Slot-in Power Distributor and rack PDU.
Benefits:
- Two feeds (A+B) possible for each rack
- Optimum power distribution from an UPS system to the rack PDUs
- Metered version: Each phase input from the Knürr PowerTrans® 2 is monitored and evaluated
- Elementary version can be fitted with a maximum of 9 plug-in units.
- To save space, the rack is only 600 mm wide
Features:
- Modular design with plug-in units that can be used as required
- Plug and Play: only the main feed must be installed by qualified electrician. The plug-in units can be inserted during operations so there are no downtimes
- High power density up to 346 kVA
- Metered version: Power distribution unit offers extensive metering function with a high level of accuracy - up to ± 1 %